Confirm the correct meter and its utility instructions, then record the cumulative reading exactly as shown, its units and the date and time. Compare totals only from the same meter, display mode and units. Note known water use; a change alone does not locate a leak.

Report outside surfacing water before collecting another reading
If water is surfacing in a yard, beside a meter area or near a road, report the location and safe observations to the serving utility before trying to complete a meter log. Keep away from soft ground, flowing water, damaged covers and electrical hazards; do not open a flooded box to obtain digits.
The outside-water response guide adds a reporting table and private case record. A meter change is useful context when already available safely, but does not identify the source or repair responsibility. Keep any pressure change, official advisory, investigation result and later usage question as separate entries.
Confirm the meter and a safe way to read it
Start with your water utility’s instructions for your property and meter model. In a shared building, do not assume the nearest meter belongs to your dwelling. Ask the utility or building manager to resolve identity and access first.
Use a utility-provided reading or customer record when physical access is uncertain. Meter-box covers can be heavy and the space can contain animals, as Portland Water Bureau cautions. Mesa also warns that some smart-meter lids have wires attached. This guide does not ask you to lift a heavy cover, enter a flooded box, detach anything or operate a valve.
If the meter cannot be read safely without moving equipment, opening restricted access or reaching near an electrical hazard, stop and ask the utility for help. A complete log is less important than safe access.
Find the cumulative total, not just a changing screen
A cumulative consumption reading adds up water that has passed through the meter. An instantaneous flow screen describes a rate at that moment. Those numbers have different meanings and cannot be subtracted from one another.
Some displays cycle through several screens. Mesa’s instructions show different billing-digit conventions for different models, so “ignore the last three digits” is not a universal rule. Keep the full raw reading, decimal position and displayed units in your own record until the utility confirms how they relate to its bill.
Cave Creek’s ProCoder T-10 sheet is a specific example: its totalizer records gallons, while billing uses thousands of gallons. That example does not identify the units, display precision or billing conversion on your meter. Use the instructions for the actual meter and utility.
Make two readings comparable
Choose one clearly identified source and display mode. Record the time as well as the date. If you use a utility portal, distinguish the time the usage was measured from the time you opened the page, and note whether the record is estimated or actual when that is shown.
The following is an editorial log format. It keeps the information needed to ask a useful question without assuming every utility provides the same display or online tools.
| Record | What to write |
|---|---|
| Date and time | When the reading represents, plus any reporting delay shown |
| Meter reference | Your private reference for the same confirmed meter |
| Source and mode | Meter cumulative screen or identified utility record |
| Raw reading and units | All visible digits, decimal position and confirmed unit |
| Known use since last entry | Laundry, irrigation, guests or other relevant use |
| Difference / unresolved question | Comparable subtraction, or the reason comparison must wait |
Example: calculate a difference without diagnosing it
Fictional example: a confirmed gallons total reads 071500.0 at 8 a.m. Sunday and 071620.0 at 8 a.m. Monday. The same meter and cumulative display were used both times. Subtracting 71,500.0 from 71,620.0 gives 120 gallons over 24 hours.
The household notes two laundry loads and its other ordinary water use during that interval. Those notes provide context; this example does not establish whether 120 gallons is normal for another home, how much it costs or whether a leak exists.
If the second value is smaller, do not simply report negative consumption. First resolve a changed meter, wrong screen, different units, transcription error or another explanation with the utility. Similarly, a rounded billing read may conceal small changes visible in a more precise total.
Use an unexpected change as a question
If readings move during a period when you expected no use, note what automatic equipment might have operated and ask your utility about its leak-check procedure. An unexplained difference is evidence to investigate, not a location or cause.
Do not force a no-use experiment that interrupts equipment with special operating requirements. Do not disassemble plumbing or operate an unfamiliar shutoff to complete a reading log. Use qualified help when the cause or safe next step is unclear.
An unchanged reading over one interval does not rule out intermittent use or every kind of leak. A water alarm, visible escape of water or an electrical hazard deserves an appropriate response even if a meter record looks unchanged. The leak-alarm response guide covers that separate situation.
Bring a focused question to the utility
Keep the original entries and ask: “Are these the same cumulative units, and how does this display map to the consumption on my bill?” Include the reading times and relevant known use through the utility’s normal private contact channel.
For a higher bill, compare billing days, recorded consumption and rate or fee changes separately using the rising-water-bill guide. A meter log supplies one part of that explanation. It does not validate meter accuracy, settle a bill or authorize access to utility equipment.
- Correct meter and applicable utility instructions confirmed: ___.
- Safe source of the reading identified: ___.
- Same cumulative mode and units for both entries: ___.
- Times, raw readings and known use saved: ___.
- Unresolved question and next contact: ___.
When to call a professional
Stop and contact a qualified plumber or other appropriate professional if water is actively spreading, you cannot safely find the shutoff, the leak involves a wall or ceiling, or a repair would require changing plumbing.
Related guides
Sources
- WSSC Water: Residential Tips — underground leak investigation and local service responsibilities
- City of Greenbelt: Water Emergencies — outdoor reporting, unsafe ground and local notice limits
- City of Mesa: Reading your Utility Meter & Identifying Leaks
- Town of Cave Creek: How to Read the ProCoder T-10 Water Meter (model-specific PDF)
- Portland Water Bureau: How to check for leaks
Free next step
Download the free seasonal maintenance checklist to record observations and follow-up tasks. See the seasonal maintenance routine for more context.
Affiliate disclosure
No affiliate links appear in this guide. If a reviewed recommendation is added, the disclosure will appear beside it.